For this module the ubiquitin system was deliberately broken, one thing at a time, and run with GROMACS in the cloud: five "loud" cases (grompp or mdrun stops) and three "silent" cases (the run finishes but the setup is wrong). The messages and numbers on the page are taken verbatim from these runs. The run and analysis plan was written before the runs and frozen with SHA-256; the results were independently checked with GROMACS tools. The western blot bridge is a rule-based teaching model running in your browser. Anything not computed is labeled "This scenario was not computed".
MD-FAIL · When a simulation fails

Did the run stop, or did it silently finish wrong?

A simulation fails in two ways. In a loud failure grompp or mdrun stops and writes a message; where the message points is often the symptom, and the cause sits at an earlier step. In a silent failure the run finishes without errors and the log contains no warnings at all, but the target temperature was mistyped or the solvent was forgotten. On this page you will see both with real runs.

Discoveries: 0 / 8
Experimental bridge

Western blot: no band. Why?

The band of the target protein does not appear in the sample lane. There are four possible causes: the transfer failed, the primary antibody is degraded, the target protein really is absent from this sample, or the detection reagent is degraded. The symptom is the same in all four. Choose checks, look at their results and decide on the cause. Each new case picks the hidden cause again.

Which cause?

Open

Symptom and cause

Solve at least two cases.

1 · Workshop: loud failures

Five corruptions, five real GROMACS messages

In each case one thing in the system was broken and the command was run. Below are the command, the exit code and the relevant part of the message GROMACS wrote. Read the message and decide what the real problem is; then the fix and the result of the fixed command appear. Exit code 0 means success; any other value means the program stopped.

Open

What the message says, and the real cause

Answer cases 1 and 2.

Open

Warning and symptom

Answer cases 3 and 4.

Open

A crash at step 0

Answer case 5.

2 · Workshop: silent failures

The run finished, the log is clean. Is the setup right?

One change was made to the production settings each time, and 200 ps were run from the same equilibrated state. In S1 the position restraint left over from equilibration was kept on (define = -DPOSRES), in S2 the target temperature was typed as 30 instead of 300 (ref_t = 30), in S3 the water was removed from the topology and the coordinates. The gray lines are three correct runs of the same system (MD-MET, 0 to 200 ps). Choose a case and a measure.

Case:
Measure:

Fluctuation per residue (100 to 200 ps)

Open

A "silent" case that was not silent

Open S1.

Open

A "more stable" protein at 30 K

Open S2 and look at the temperature.

Open

Without water

Open S3 and look at at least three measures.

3 · Bench: reading logs

Six real fragments: what do they say?

Each fragment was taken from the files of the runs on this page: ends of md.log, the topology, grompp and mdrun output. Choose the best reading for each; then the reasoning appears.

Open

Finished does not mean right

Judge at least four fragments.

4 · Notebook: run health record

Six lines written before looking at the results

Fill this in after every production run, before interpreting structure or energy; the examples are from this page. Missing lines trigger notes at the bottom. The text is generated only in your browser and is not sent anywhere.


  
5 · Quiz

Six questions

Sources and limits

Terms in this module

The definition of each term and the other modules where it appears are in the glossary.