Noise is counted as transitions
Try both counting methods and at least two noise levels.
It is tempting to describe a trajectory as "a molecule hopping between two states" or as "the sum of a few large motions". But states are not waiting in the data; we draw the boundary, and where it lies changes the number of transitions and the lifetimes. The first PCA component is the direction of largest variance; it may be a functional motion, the wandering of a flexible tail or the trace of insufficient sampling. A correlation map, in turn, is computed in a fitting frame. On this page you will test these three choices with real data.
In a single-molecule FRET experiment the two conformations of a molecule give different efficiency values, and the trace jumps between these two levels over time. The measurement is noisy. How do you count the transitions and the dwell time in each state? The trace below is a teaching model: a two-state process is generated in your browser and noise is added on top; the true number of transitions in the model is known. Compare counting with one threshold and with two thresholds (a band in between; points inside the band are assigned to the previous state).
Try both counting methods and at least two noise levels.
Each of the three mdshare ALA2 runs contains 250,000 frames (1 ps spacing). The box definition (MD-U) divides the φ/ψ plane into three regions; each frame takes the state of the region it lies in. In the core set definition each state has a core of radius r around its center; a frame moves to a new state only when it is inside a core, and frames between cores keep the state of the last core visited (Buchete and Hummer 2008). The map shows 25,000 frames (10 ps spacing) from run 1; the table was computed from all frames.
The same 25,000 frames were given to k-means as the sines and cosines of the angles (scikit-learn, 10 initializations). You choose the number of clusters k; the algorithm draws the boundaries itself.
Compare the box definition with at least two core radii.
Read the fractions and lifetimes in the table together.
Look at k = 3 and k = 4.
In the three independent ubiquitin runs of MD-MET (200 to 2000 ps, 901 frames per run) the Cα coordinates were fitted to the crystal on the core (residues 1 to 70) and the eigenvectors of the covariance matrix (principal components) were computed. There are two atom sets: all 76 Cα and the core only. The 3D view shows motion along PC1, moving back and forth over the projection range of the run; you can pause it and stop at a projection value with the slider.
Compare the all-Cα and core-Cα sets.
Look at the projections of the three runs and at the pooled view.
The dynamic cross-correlation map (DCCM; Ichiye and Karplus 1991) shows how much the deviations of each residue pair around their mean positions point in the same direction: +1 the same direction, −1 opposite directions. The deviations are computed after a fit. Compare two fits (to the crystal on core Cα and on all Cα) and three runs. The block between loop 7 to 11 and tail 71 to 76 is outlined on the map.
Look at both fits and at least two runs.
Decide for each sentence: supported by the data on this page, needs more evidence, or not supported by these data. After your choice the rationale and the relevant result appear.
Decide on at least four sentences.
The state definition and the PCA settings are written before the results are seen. Fill them in for your own study; the examples come from this page. The text is created only in your browser and is not sent anywhere.
The definition of each term and the other modules where it appears are in the glossary.